Power Blower
Operator's Manual
MODEL PB-250
X750012944
12/11
X7501182004
WARNING
Users of this equipment risk injury to themselves and others if the unit is used im-
properly and/or safety precautions are not followed. ECHO provides an operators
manual. It must be read and understood for proper and safe operation. Failure to do
so could result in serious injury.
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - Power Blower

Power BlowerOperator's Manual MODEL PB-250 X75001294412/11X7501182004 WARNINGUsers of this equipment risk injury to themselves and others i

Page 2 - operaTor's manual

10 WARNINGMoving parts can amputate ngers or cause severe injuries. Keep hands, clothing and loose objects away from all openings. Always stop engi

Page 3 - DANGER

11Power Blower oPerator's ManualMixing Instructions 1. Fill an approved fuel container with half of the required amount of gasoline. 2. Add

Page 4

12sTarTIng Cold engIne 1. Stop Switch Move stop switch button (A) away from the STOP position. 2. Throttle Position Lever Move throttle

Page 5

13Power Blower oPerator's ManualsTarTIng warm engIneThe starting procedure is the same as Cold Start except DO NOT close the choke. 1. Stop Swit

Page 6 - & evaporaTIve)

14operaTIng blower WARNING Engine exhaust IS HOT, and contains Carbon Monoxide (CO), a poison gas. Breathing CO can cause unconsciousne, serious inj

Page 7 - 65 Category II

15Power Blower oPerator's ManualmaInTenanCe InTervalsmaInTenanCeYour ECHO blower is designed to provide many hours of trouble free service. Regul

Page 8 - ConTenTs

16aIr fIlTerLevel 1.Parts required: REPOWERTM Air and Filter KitNOTE Clean daily. 1. Close choke (Cold Start Position [ ]). This prevents dirt f

Page 9 - blower pIpes

17Power Blower oPerator's ManualCoolIng sysTemLevel 2.Parts Required: None, if you are careful. IMPORTANT To maintain proper engine operatin

Page 10 - WARNING

18Cleaning Cylinder Fins 1. Remove spark plug lead from spark plug, and remove engine cover (6 screws). Clean cylinder ns to allow cooling air t

Page 11 - 's Manual

19Power Blower oPerator's ManualABExhaust Port CleaningLevel 2.Parts Required: As needed: Heat Shield1. Remove spark plug lead from spark pl

Page 12 - Cold engIne

2Table of ConTenTsIntroduction ...2 - The Operator's Manual ...

Page 13 - engIne

20CarbureTor adjusTmenTEngine Break-InNew engines must be operated a minimum duration of two tanks of fuel break-in before carburetor adjustments can

Page 14 - WARNING

21Power Blower oPerator's ManualTroubleshooTIng WARNINGFuel vapors are extremely ammable and may cause re and/or explosion. Never test for i

Page 15

22sTorage WARNINGDuring operation the mufer or catalytic mufer and surrounding cover becomes hot. Always keep exhaust area clear of ammable debris

Page 16 - DANGER

23Power Blower oPerator's ManualspeCIfICaTIonsMODEL ---------------------------------------------------- PB-250 Hand HeldLength ----------------

Page 17 - (0.026 in.)

24warranTy sTaTemenTsECHO LIMITED WARRANTY STATEMENT FOR PRODUCT SOLD IN USA AND CANADA BEGINNING 01/01/2010ECHO'S RESPONSIBILITYECHO Incorporate

Page 18 - Spark Arrestor Screen

25Power Blower oPerator's ManualPURCHASED REPAIR PARTS, SHORT BLOCKS AND ACCESSORIES

Page 19

26 ECHO INCORPORATED EMISSION CONTROL WARRANTY STATEMENTFOR ECHO AND SHINDAIWA BRANDSThe Environmental Protection Agency (EPA) and the California Air

Page 20 - adjusTmenT

27Power Blower oPerator's ManualnoTes

Page 21 - TroubleshooTIng

CONSUMER PRODUCTSUPPORT1-800-673-15588:30 - 4:30 Mon - Fri C.S.T.ECHO, INCORPORATED400 OakwOOd ROadlake ZurICh, Il 60047-1564www.echo-usa.comDEALER?

Page 22 - DANGER

3Power Blower oPerator's ManualsafeTymanual safeTy symbols and ImporTanT InformaTIon Throughout this manual and on the product itself, you will 

Page 23

4Physical Condition Your judgment and physical dexterity may not be good: • if you are tired or sick,

Page 24

5Power Blower oPerator's Manual DANGERDo not operate this product indoors or in inadequately ventilated areas. Engine exhaust contains poisonous

Page 25

6equIpmenT CheCk WARNINGUse only ECHO approved attachments. Serious injury may result from the use of a non-approved attachment combi-nation. ECHO,

Page 26 - 99922201033

7Power Blower oPerator's ManualdesCrIpTIonLocate the safety decals on your unit. Make sure the decals are legible and that you understand and fo

Page 27

8 1. SAFETY DECAL - Lists important safety precautions. 2. STOP SWITCH - "SLIDE SWITCH" mounted on top of handle. Push forward to start a

Page 28 - 1-800-432-3246

9Power Blower oPerator's Manualassembly WARNINGNever perform maintenance or assembly procedures with engine running or serious personal injury