Power BlowerOperator's Manual MODEL PB-250 X75001294412/11X7501182004 WARNINGUsers of this equipment risk injury to themselves and others i
10 WARNINGMoving parts can amputate ngers or cause severe injuries. Keep hands, clothing and loose objects away from all openings. Always stop engi
11Power Blower oPerator's ManualMixing Instructions 1. Fill an approved fuel container with half of the required amount of gasoline. 2. Add
12sTarTIng Cold engIne 1. Stop Switch Move stop switch button (A) away from the STOP position. 2. Throttle Position Lever Move throttle
13Power Blower oPerator's ManualsTarTIng warm engIneThe starting procedure is the same as Cold Start except DO NOT close the choke. 1. Stop Swit
14operaTIng blower WARNING Engine exhaust IS HOT, and contains Carbon Monoxide (CO), a poison gas. Breathing CO can cause unconsciousne, serious inj
15Power Blower oPerator's ManualmaInTenanCe InTervalsmaInTenanCeYour ECHO blower is designed to provide many hours of trouble free service. Regul
16aIr fIlTerLevel 1.Parts required: REPOWERTM Air and Filter KitNOTE Clean daily. 1. Close choke (Cold Start Position [ ]). This prevents dirt f
17Power Blower oPerator's ManualCoolIng sysTemLevel 2.Parts Required: None, if you are careful. IMPORTANT To maintain proper engine operatin
18Cleaning Cylinder Fins 1. Remove spark plug lead from spark plug, and remove engine cover (6 screws). Clean cylinder ns to allow cooling air t
19Power Blower oPerator's ManualABExhaust Port CleaningLevel 2.Parts Required: As needed: Heat Shield1. Remove spark plug lead from spark pl
2Table of ConTenTsIntroduction ...2 - The Operator's Manual ...
20CarbureTor adjusTmenTEngine Break-InNew engines must be operated a minimum duration of two tanks of fuel break-in before carburetor adjustments can
21Power Blower oPerator's ManualTroubleshooTIng WARNINGFuel vapors are extremely ammable and may cause re and/or explosion. Never test for i
22sTorage WARNINGDuring operation the mufer or catalytic mufer and surrounding cover becomes hot. Always keep exhaust area clear of ammable debris
23Power Blower oPerator's ManualspeCIfICaTIonsMODEL ---------------------------------------------------- PB-250 Hand HeldLength ----------------
24warranTy sTaTemenTsECHO LIMITED WARRANTY STATEMENT FOR PRODUCT SOLD IN USA AND CANADA BEGINNING 01/01/2010ECHO'S RESPONSIBILITYECHO Incorporate
25Power Blower oPerator's ManualPURCHASED REPAIR PARTS, SHORT BLOCKS AND ACCESSORIES
26 ECHO INCORPORATED EMISSION CONTROL WARRANTY STATEMENTFOR ECHO AND SHINDAIWA BRANDSThe Environmental Protection Agency (EPA) and the California Air
27Power Blower oPerator's ManualnoTes
CONSUMER PRODUCTSUPPORT1-800-673-15588:30 - 4:30 Mon - Fri C.S.T.ECHO, INCORPORATED400 OakwOOd ROadlake ZurICh, Il 60047-1564www.echo-usa.comDEALER?
3Power Blower oPerator's ManualsafeTymanual safeTy symbols and ImporTanT InformaTIon Throughout this manual and on the product itself, you will
4Physical Condition Your judgment and physical dexterity may not be good: • if you are tired or sick,
5Power Blower oPerator's Manual DANGERDo not operate this product indoors or in inadequately ventilated areas. Engine exhaust contains poisonous
6equIpmenT CheCk WARNINGUse only ECHO approved attachments. Serious injury may result from the use of a non-approved attachment combi-nation. ECHO,
7Power Blower oPerator's ManualdesCrIpTIonLocate the safety decals on your unit. Make sure the decals are legible and that you understand and fo
8 1. SAFETY DECAL - Lists important safety precautions. 2. STOP SWITCH - "SLIDE SWITCH" mounted on top of handle. Push forward to start a
9Power Blower oPerator's Manualassembly WARNINGNever perform maintenance or assembly procedures with engine running or serious personal injury
Comments to this Manuals